HFS-SS Series
Stainless Steel Floor Scale
Washdown-rated stainless steel platform scale for hygienic environments — food, pharma, and chemical processing.
- Capacity range
- 0.5–1 T
- Category
- Industrial Floor Scales
- Technical details
- Available below

Manufacturing
Built, installed & supported by HMT
Compliance support
Calibration & Legal Metrology guidance
System ready
Automation, ticketing & ERP integration
01Overview
Full stainless-steel construction (deck, load cells, and junction box) rated for washdown cleaning, where a mild-steel deck would corrode or fail hygiene audits.
02How it works
Coved corners eliminate the crevices bacteria hide in
A standard welded corner or a sharp internal angle on a deck is exactly the kind of spot where product residue, moisture, and bacteria accumulate and are hard to fully clean out. A coved corner — a smooth, radiused transition instead of a sharp angle — removes that harborage point entirely, which is why hygienic equipment design standards across food and pharma consistently specify coved rather than square internal corners.
IP68 vs IP69K — two different kinds of wet
IP68 rates protection against continuous submersion in water; IP69K rates protection against high-pressure, high-temperature washdown spray, the kind used in food and pharma sanitation routines. A washdown environment needs the IP69K rating specifically, because a hose spraying hot water at pressure is a materially different stress on a seal than simple submersion — a scale genuinely rated for washdown carries both ratings rather than just one.
Stainless load cells protect the weakest link
A load cell's strain gauge and internal electronics are the most failure-prone part of any scale if moisture reaches them — a mild-steel load cell body corroding at its seals is a common failure mode in a wash-down environment, so building the load cells themselves from stainless steel and hermetically sealing them removes that vulnerability at its source, not just at the visible deck surface.

03Manufacturing & build quality
The deck, frame, and load cell housings are fabricated entirely from stainless steel, welded with coved-corner detailing at every internal joint to eliminate crevices, then ground and polished to a smooth, cleanable finish. Load cells are hermetically sealed to IP68/IP69K rating, meaning their internal electronics are protected against both submersion and high-pressure, high-temperature washdown spray — a materially more demanding seal than a standard IP65 enclosure. The junction box is likewise stainless and washdown-rated, and the complete assembly is tested for both weighing accuracy and seal integrity — including a simulated washdown test — before it's calibrated and shipped as a complete system.
04Problems it solves
Mild steel corrosion failing hygiene audits
A mild-steel deck in a wet or chemically-cleaned environment corrodes visibly over time, and visible corrosion is a direct hygiene audit failure point in food and pharma facilities — full stainless construction removes that risk from the outset.
Bacterial harborage in seams and sharp corners
Standard fabrication with sharp internal corners creates cleaning blind spots; coved corners and a smooth finish are specifically designed to be fully cleanable with no residue trap.
Washdown chemicals degrading standard components
Aggressive cleaning chemicals used in food and pharma sanitation can degrade seals and coatings not designed for that exposure; stainless construction and properly rated seals are built to withstand that chemical environment.
Cross-contamination risk from a non-cleanable scale
In regulated production, any equipment that can't be fully and repeatedly sanitized is a contamination risk in its own right — a fully washdown-rated stainless scale is designed to be cleaned as thoroughly and as often as the rest of the production floor.
05Why it matters
In food and pharmaceutical production, a scale isn't just measurement equipment — it's a piece of production-floor equipment that has to pass the same hygiene standard as everything else it sits alongside, because a single corroded or uncleanable component anywhere in the process is a genuine audit and product-safety risk. Investing in the full stainless, properly IP68/69K-rated build isn't overspecification for these environments; it's what actually lets the scale sit on a wash-down production floor without becoming the exception that fails the next inspection.
06Salient features
- Full stainless steel deck and load cell construction
- IP68/IP69K washdown-rated junction box
- Smooth, coved-corner deck for easy cleaning
07Specifications
| Model | Capacity (T) | Least Count | Platform Size (m) | Notes |
|---|---|---|---|---|
| HFS-SS-500 | 0.5 | 0.1 kg | 1 x 1 | — |
| HFS-SS-1000 | 1 | 0.2 kg | 1.2 x 1.2 | — |
08Technical file
Need the full technical sheet?
Request drawings, model-specific details and project documentation from the HMT team. A downloadable product file will appear here once approved.
09Complete system
Plan beyond the deck.
A vehicle weighing point can combine the weighbridge with indicator, load cells, traffic management and H-Weigh software for an accountable end-to-end workflow.
08In the field

09Frequently asked
What's the practical difference between IP68 and IP69K for our facility?
IP68 covers continuous submersion; IP69K specifically covers high-pressure, high-temperature washdown spray — if your cleaning routine involves a pressure washer or steam cleaning, confirm the equipment carries IP69K specifically, not just IP68.
What cleaning chemicals is it compatible with?
Full stainless construction is broadly resistant to standard food and pharma sanitation chemicals, but check compatibility with any particularly aggressive or unusual cleaning agent your facility uses against the manufacturer's chemical resistance guidance.
What capacity range is available in stainless?
Stainless construction is offered across a broad capacity range similar to standard floor scales — the hygienic build is a material and sealing choice, not a capacity limitation.
What certifications should we look for?
Depending on your industry and market, relevant standards may include hygienic design guidelines from bodies like EHEDG or 3-A Sanitary Standards, alongside the IP68/IP69K sealing rating — confirm which specific certifications your regulatory environment requires.
Can it be installed in a genuinely wet environment full-time, not just periodic washdown?
Yes — that's the specific use case this design is built for, with sealing and material choices intended for a floor that's routinely wet, not just occasionally hosed down.
10Industries this serves
Ready to spec a stainless steel floor scale?
Tell us the application — our team responds with model recommendations, not a generic brochure.